PRACTICE LAB / FUEL
LOW 1 and LOW 2 crossfeed logic
LOW 1 opens the crossfeed and commands AC PUMP 2 to supply both engines from the right tank. LOW 2 commands AC PUMP 1 to supply both engines from the left tank. [108]
Check the pump selection
Read both tank quantities and the pump selectors. A selector outside AUTO overrides the crossfeed pump command. [108]